The Formulae for calculating application rates for
Spray boom/planter mounted sprayer -imperial
nozzle output (gal/min) x 5940
nozzle spacing (inches) x speed (mph) = application rate (galls/acre)
Knapsack Sprayer - imperial
nozzle output (gal/min) x 5940
swath width (inches) x speed (mph) = application rate (galls/acre)
The information contained in this web site is intended as a guide only to the performance that might be expected when operating stated products in the conditions stated.