You are viewing this site in staging mode. Click in this bar to return to normal site.
x#{notify_img}
#{notify_title}
#{notify_text}

Metric Table of Values for Everfan Nozzles

 

To use this chart - first determine the overall application rate from this chart based on the nozzle size, speed and nozzle spacing.
Then calculate the band application rate by multiplying the overall application rate by the appropriate constant on the Constants chart below according to the desired band width and nozzle spacing.

 

 

Colour

Tip Ref Code

Pressure
bar

Flow
litres per min

Broadcast or Overall Application Rate - litres/ hectacre

6 km/h 8 km/h 10 km/h
BCPC Code

 Nozzle row Spacing

50cm 75cm 100cm 50cm 75cm 100cm 50cm 75cm 100cm

Green

80° EF-015

2.0

0.49

98 65 49 74 49 37 59 40 30

3.0

0.60

120

80

60

90

60

45

72

48 36
F80/0.6/3

4.0

0.69

138

92

69

104

69

52

83

55 42

Yellow

80° EF-02

2.0

0.65

130 87 65 98 65 49 78 52 39

3.0

0.80

160

107

80

120

80

60

96

64 48
F80/0.8/3

4.0

0.92

184

123

92

138

92

69

110

74 55

Blue

80° EF-03

2.0

0.98

196

131

98

147

98

74

118

78 59

3.0

1.20

240

160

120

180

120

90

144

96 72
F80/1.2/3

4.0

1.39

278

185

139

209

139

104

167

111 83
Red 80° EF-04

2.0

1.31

262

175

131

197

131

98

157

105 79

3.0

1.60

320

213

160

240

160

120

192

128 96
F80/1.6/3

4.0

1.85

370

247

185

278

185

139

222

148 111

 

 

Band Width

Nozzle Height

Nozzle/Row Spacing

50 cm 75cm 100cm
20cm 12cm 2.5 3.8 5

25 cm

15cm

2 3 4

30 cm

18cm

1.7 2.5 3.3

35 cm

21cm

1.5 2.1 2.9

40 cm

24 cm

1.3 1.9 2.5

45 cm

27cm

1.1 1.7 2.2

50cm

30cm

1 1.5 2